2.3 Rear connections
Remark: Install the SIM card before you activate the system. A SIM card is not
enclosed, please contact your telecom provider to provide you with a SIM card.
Remark: Z1 and Z2 are wired zones. This is a NC (normally closed) contact. The
electrical circuit needs to be closed when idle. When the electrical circuit is interrupted
the alarm will be triggered.
Mobile SIM card holder
Input connection for wired
sensors (24-hour group)
Output for electronic lock
Open output max 100mA
Connection wired sirene
12V <500mA
Power adapter
connection
On/Off switch
Input connection for wired
sensors (normal- group)